2CHU
CeuE in complex with mecam
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-2 |
Synchrotron site | ESRF |
Beamline | ID23-2 |
Temperature [K] | 100 |
Collection date | 2005-11-05 |
Spacegroup name | P 1 |
Unit cell lengths | 73.072, 42.445, 57.523 |
Unit cell angles | 91.29, 97.06, 107.34 |
Refinement procedure
Resolution | 69.170 - 2.400 |
R-factor | 0.174 |
Rwork | 0.170 |
R-free | 0.24600 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.019 |
RMSD bond angle | 1.693 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | MOLREP |
Refinement software | REFMAC (5.2.0005) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 69.120 | 2.530 |
High resolution limit [Å] | 2.000 | 2.400 |
Rmerge | 0.080 | 0.340 |
Number of reflections | 23425 | |
<I/σ(I)> | 13.2 | 3.7 |
Completeness [%] | 91.7 | 91.2 |
Redundancy | 3.6 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.5 | 20% PEG 3350, 2.5 MM ZINC ACETATE, MECAM, 10 MM TRIS, 75 MM NACL, pH 7.50 |