2BY5
Is radiation damage dependent on the dose-rate used during macromolecular crystallography data collection
Experimental procedure
| Experimental method | SINGLE WAVELENGTH | 
| Source type | SYNCHROTRON | 
| Source details | ESRF BEAMLINE ID29 | 
| Synchrotron site | ESRF | 
| Beamline | ID29 | 
| Temperature [K] | 100 | 
| Spacegroup name | P 21 21 21 | 
| Unit cell lengths | 54.259, 58.337, 66.745 | 
| Unit cell angles | 90.00, 90.00, 90.00 | 
Refinement procedure
| Resolution | 19.800 - 1.300 | 
| R-factor | 0.104 | 
| Rwork | 0.103 | 
| R-free | 0.13800 | 
| Structure solution method | OTHER | 
| RMSD bond length | 0.018 | 
| RMSD bond angle | 2.431 | 
| Data reduction software | MOSFLM | 
| Data scaling software | SCALA | 
| Refinement software | REFMAC (5.2.0003) | 
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 1.370 | 
| High resolution limit [Å] | 1.300 | 1.300 | 
| Rmerge | 0.060 | 0.220 | 
| Number of reflections | 52088 | |
| <I/σ(I)> | 12.2 | 4 | 
| Completeness [%] | 98.9 | 98.8 | 
| Redundancy | 3.8 | 2.8 | 
Crystallization Conditions
| crystal ID | method | pH | temperature | details | 
| 1 | 25% PEG 8000, 0.2 M AMMONIUM SULPHATE, 0.1 M TRIS-HCL PH 8.0 | 