2BY3

Is radiation damage dependent on the dose-rate used during macromolecular crystallography data collection

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Spacegroup nameP 21 21 21
Unit cell lengths59.505, 66.645, 152.996
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 1.500
R-factor0.168
Rwork0.167
R-free0.20400
Structure solution methodOTHER
RMSD bond length0.021
RMSD bond angle1.831
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Refinement softwareREFMAC (5.2.0003)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.580
High resolution limit [Å]1.5001.500
Rmerge0.1101.090
Number of reflections98176
<I/σ(I)>9.51
Completeness [%]100.0100
Redundancy3.93.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
120% PEG 2000 MME, 0.1 M TRIS-HCL PH 8.5, 5% GLYCEROL AND 0.1 M MGCL2

223790