2BY2
Is radiation damage dependent on the dose-rate used during macromolecular crystallography data collection
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 100 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 59.418, 66.529, 152.522 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 1.500 |
R-factor | 0.149 |
Rwork | 0.148 |
R-free | 0.17700 |
Structure solution method | OTHER |
RMSD bond length | 0.015 |
RMSD bond angle | 1.634 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Refinement software | REFMAC (5.2.0003) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.580 |
High resolution limit [Å] | 1.500 | 1.500 |
Rmerge | 0.080 | 0.380 |
Number of reflections | 97798 | |
<I/σ(I)> | 13 | 3.1 |
Completeness [%] | 100.0 | 100 |
Redundancy | 4 | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 20% PEG 2000 MME, 0.1 M TRIS-HCL PH 8.5, 5% GLYCEROL AND 0.1 M MGCL2 |