Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2BK8

M1 domain from titin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsEMBL/DESY, HAMBURG BEAMLINE X11
Synchrotron siteEMBL/DESY, HAMBURG
BeamlineX11
Temperature [K]100
Detector technologyCCD
Collection date2004-11-16
DetectorMARRESEARCH
Spacegroup nameI 41
Unit cell lengths68.780, 68.780, 48.180
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution17.740 - 1.690
R-factor0.191
Rwork0.189
R-free0.23400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)HOMOLOGY MODEL
RMSD bond length0.015
RMSD bond angle1.393
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareAMoRE
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]17.7401.800
High resolution limit [Å]1.6901.690
Rmerge0.0400.410
Number of reflections24619
<I/σ(I)>18.13.89
Completeness [%]99.6100
Redundancy3.83.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
172.2 M AMMONIUM SULFATE 0.1 M BIS TRIS PH 7.0

218853

PDB entries from 2024-04-24