2B2H
Ammonium Transporter Amt-1 from A. fulgidus (AS)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2005-05-13 |
| Detector | MARRESEARCH |
| Wavelength(s) | 1.5418 |
| Spacegroup name | H 3 |
| Unit cell lengths | 111.408, 111.408, 136.644 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 100.000 - 1.540 |
| R-factor | 0.154 |
| Rwork | 0.154 |
| R-free | 0.16900 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2b2f |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.194 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 100.000 | 1.640 |
| High resolution limit [Å] | 1.540 | 1.540 |
| Number of reflections | 92426 | |
| Completeness [%] | 98.7 | 93.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 298 | PEG 400, Tris/HCl, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K |