2AEH
Focal adhesion kinase 1
Experimental procedure
| Experimental method | MAD |
| Source type | SYNCHROTRON |
| Source details | CHESS BEAMLINE F2 |
| Synchrotron site | CHESS |
| Beamline | F2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2002-05-03 |
| Detector | CUSTOM-MADE |
| Wavelength(s) | 0.9796,0.9793,0.95004 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 44.213, 146.231, 68.919 |
| Unit cell angles | 90.00, 96.37, 90.00 |
Refinement procedure
| Resolution | 20.000 - 2.530 |
| R-factor | 0.21 |
| Rwork | 0.206 |
| R-free | 0.24900 |
| Structure solution method | MAD |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | SOLVE |
| Refinement software | CNS (1.0) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 28.600 | 2.570 |
| High resolution limit [Å] | 2.500 | 2.530 |
| Rmerge | 0.073 | |
| Number of reflections | 29870 | |
| <I/σ(I)> | 22.5 | 2.7 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 4.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 298 | 100 mM Tris pH 8.0, 16-22% PEG 4000, 20% glycerol, 200 mM NaCl, 100 mM CsCl, 10 mM DTT, VAPOR DIFFUSION, HANGING DROP, temperature 298K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 298 | 100 mM Tris pH 8.0, 16-22% PEG 4000, 20% glycerol, 200 mM NaCl, 100 mM CsCl, 10 mM DTT, VAPOR DIFFUSION, HANGING DROP, temperature 298K |