Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2A7H

On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 5.2R
Synchrotron siteELETTRA
Beamline5.2R
Temperature [K]100
Spacegroup nameP 31 2 1
Unit cell lengths54.190, 54.190, 105.860
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution30.000 - 2.100
R-factor0.166
Rwork0.166
R-free0.23000
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.025
RMSD bond angle2.186
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 Overall
Low resolution limit [Å]30.000
High resolution limit [Å]2.100
Number of reflections10801
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

222036