POTASSIUM CHANNEL FROM MAGNETOSPIRILLUM MAGNETOTACTICUM

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX1
Synchrotron siteAustralian Synchrotron
BeamlineMX1
Temperature [K]100
Detector technologyCCD
Collection date2008-11-10
DetectorADSC CCD
Spacegroup nameC 2 2 21
Unit cell lengths99.261, 151.193, 294.757
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.971 - 3.610
R-factor0.2645
Rwork0.263
R-free0.28810
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1xl4
RMSD bond length0.006
RMSD bond angle1.035
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.730
High resolution limit [Å]3.6003.600
Rmerge0.1300.460
Number of reflections25733
<I/σ(I)>123.8
Completeness [%]94.792
Redundancy6.36
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6PRECIPITANT 40 % PEG 200 0.2 M SODIUM CHLORIDE 0.1 M SODIUM PHOSPHATE PH 6.0 PROTEIN KIRBAC3.1, 8MG/ML 150MM KCL 20MM BACL2 4MM LDAO 0.05% TDM 0.2MM PI(4,5)P2 PROTEIN AND PRECIPITANT WERE COMBINED IN A 1:1 RATIO AND EQUILIBRATED AGAINST A RESERVOIR OF PRECIPITANT IN A SITTING DROP VAPOUR DIFFUSION SET UP.

219869

PDB entries from 2024-05-15