2WD5
SMC hinge heterodimer (Mouse)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-04-10 |
Detector | ADSC CCD |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 52.285, 61.867, 77.046 |
Unit cell angles | 90.00, 105.04, 90.00 |
Refinement procedure
Resolution | 26.050 - 2.700 |
R-factor | 0.229 |
Rwork | 0.225 |
R-free | 0.30500 |
Structure solution method | SAD |
Starting model (for MR) | NONE |
RMSD bond length | 0.007 |
RMSD bond angle | 1.023 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | SHARP |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 26.000 | 2.850 |
High resolution limit [Å] | 2.700 | 2.700 |
Rmerge | 0.120 | 0.550 |
Number of reflections | 10243 | |
<I/σ(I)> | 6 | 1.7 |
Completeness [%] | 94.6 | 95.6 |
Redundancy | 2.5 | 2.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |