2VXO
Human GMP synthetase in complex with XMP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-05-27 |
Detector | MARMOSAIC 225 mm CCD |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 98.520, 123.420, 127.960 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.920 - 2.500 |
R-factor | 0.206 |
Rwork | 0.203 |
R-free | 0.25600 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2ywc |
RMSD bond length | 0.009 |
RMSD bond angle | 1.203 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.5.0036) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.560 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.090 | 0.587 |
Number of reflections | 54472 | |
<I/σ(I)> | 19 | 4.12 |
Completeness [%] | 99.7 | 100 |
Redundancy | 7.7 | 7.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.2 | 0.1M NAAC,PH 5.2,1.6M AMSO4, 0.2M NACL |