2R9N
Cathepsin S complexed with Compound 26
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Detector | RIGAKU RAXIS IIC |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 41 2 2 |
| Unit cell lengths | 85.296, 85.296, 149.961 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.000 - 2.000 |
| Rwork | 0.183 |
| R-free | 0.22000 |
| Starting model (for MR) | 1ms6 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.300 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR (98.1) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.000 |
| Number of reflections | 38189 |
| Completeness [%] | 100.0 |
| Redundancy | 14.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 298 | 100mM NaOAc, 18-35% PEG MME (500-8000), 2 M (NH4)2SO4 with or without 15% glycerol, pH 4.6, vapor diffusion, hanging drop, temperature 298K |