2I0V
c-FMS tyrosine kinase in complex with a quinolone inhibitor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | OTHER |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2003-09-09 |
| Detector | BRUKER SMART 6000 |
| Wavelength(s) | 1.5418 |
| Spacegroup name | H 3 |
| Unit cell lengths | 82.199, 82.199, 143.300 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 26.590 - 2.800 |
| R-factor | 0.266 |
| Rwork | 0.237 |
| R-free | 0.29600 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.500 |
| Data reduction software | SAINT |
| Data scaling software | LSCALE |
| Phasing software | CNX (2000) |
| Refinement software | CNX (2005) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 41.100 | 2.800 |
| High resolution limit [Å] | 2.690 | 2.690 |
| Number of reflections | 9834 | |
| <I/σ(I)> | 6.35 | |
| Completeness [%] | 98.6 | 95.4 |
| Redundancy | 4.37 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.2 | 298 | PEG 3350, sodium acetate, Li2SO4, pH 5.2, VAPOR DIFFUSION, HANGING DROP, temperature 298K |