2HRL
Siglec-7 in complex with GT1b
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-4 |
Synchrotron site | ESRF |
Beamline | ID14-4 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-04-24 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 0.9756 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 46.021, 46.021, 106.474 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 15.000 - 1.850 |
R-factor | 0.19678 |
Rwork | 0.195 |
R-free | 0.23447 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1o7v |
RMSD bond length | 0.011 |
RMSD bond angle | 1.486 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | REFMAC (5.1.24) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 15.000 | 1.920 |
High resolution limit [Å] | 1.850 | 1.850 |
Rmerge | 0.073 | 0.520 |
Number of reflections | 11626 | |
<I/σ(I)> | 25.5 | 2.3 |
Completeness [%] | 98.3 | 98.4 |
Redundancy | 3.6 | 2.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 293 | 200mM sodium acetate, 100mM sodium cacodylate, 30 % w/v PEG 8000, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K |