Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2ECS

Lambda Cro mutant Q27P/A29S/K32Q at 1.4 A in space group C2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-2
Synchrotron siteSSRL
BeamlineBL9-2
Temperature [K]100
Detector technologyCCD
Collection date2006-07-19
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)0.97946
Spacegroup nameC 1 2 1
Unit cell lengths88.689, 26.999, 55.523
Unit cell angles90.00, 103.69, 90.00
Refinement procedure
Resolution53.920 - 1.400
R-factor0.141
Rwork0.139
R-free0.17500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)Lambda Cro Q27P/A29S/K32Q at 1.35 A resolution in space group P3221
RMSD bond length0.014
RMSD bond angle1.505
Data reduction softwareCrystalClear
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]53.9461.480
High resolution limit [Å]1.4001.400
Rmerge0.0740.416
Total number of observations19965
Number of reflections25562
<I/σ(I)>5.81.7
Completeness [%]99.8100
Redundancy5.55.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.529880% saturated lithium sulfate, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 298.0K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon