Experimental procedure
| Source type | ROTATING ANODE |
| Source details | SIEMENS |
| Temperature [K] | 293 |
| Detector technology | IMAGE PLATE |
| Collection date | 1995-05-01 |
| Detector | RIGAKU RAXIS IIC |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 73.500, 84.800, 80.300 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 10.000 - 2.800 |
| R-factor | 0.193 |
| Rwork | 0.193 |
| R-free | 0.27600 |
| RMSD bond length | 0.013 |
| RMSD bond angle | 1.897 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 10.000 |
| High resolution limit [Å] | 2.800 |
| Rmerge | 0.143 |
| Number of reflections | 11995 |
| Completeness [%] | 99.0 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 6.7 | pH 6.7 |