2AGO
Fidelity of Dpo4: effect of metal ions, nucleotide selection and pyrophosphorolysis
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 95 |
Detector technology | IMAGE PLATE |
Collection date | 2004-12-29 |
Detector | RIGAKU RAXIS IV |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 99.044, 101.939, 53.017 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.000 - 2.850 |
R-factor | 0.22 |
Rwork | 0.220 |
R-free | 0.26300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1jx4 |
Refinement software | CNS |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 2.850 |
Number of reflections | 12652 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |