28VW
Human galectin 3 apo in ammonium formate buffer
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID30B |
| Synchrotron site | ESRF |
| Beamline | ID30B |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2026-02-10 |
| Detector | DECTRIS EIGER2 X 16M |
| Wavelength(s) | 0.9677 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 36.471, 57.658, 62.275 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 31.470 - 1.090 |
| Rwork | 0.133 |
| R-free | 0.15250 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 1.391 |
| Data reduction software | DIALS (3.23.0-g7aff524e7-release) |
| Data scaling software | Aimless (0.8.2) |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0431 (refmacat 0.4.126)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 31.470 | 31.470 | 1.110 |
| High resolution limit [Å] | 1.090 | 5.970 | 1.090 |
| Rmerge | 0.107 | 0.077 | 0.855 |
| Rmeas | 0.122 | 0.090 | 1.065 |
| Rpim | 0.059 | 0.045 | 0.624 |
| Number of reflections | 54684 | 406 | 2320 |
| <I/σ(I)> | 10.6 | 20.7 | 3 |
| Completeness [%] | 98.6 | 99.4 | 86.3 |
| Redundancy | 7.9 | 6.7 | 4.9 |
| CC(1/2) | 0.989 | 0.990 | 0.661 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 20%Peg 3350, 200mM ammonium formate |