21IE
The MIDN Catch-IRF4 (A8S) fusion protein
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL10U2 |
| Synchrotron site | SSRF |
| Beamline | BL10U2 |
| Temperature [K] | 193 |
| Detector technology | PIXEL |
| Collection date | 2025-12-08 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.97918 |
| Spacegroup name | P 65 2 2 |
| Unit cell lengths | 88.617, 88.617, 72.117 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 44.310 - 3.240 |
| R-factor | 0.2792 |
| Rwork | 0.278 |
| R-free | 0.29400 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.013 |
| RMSD bond angle | 1.685 |
| Data reduction software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.2_5419) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 44.310 | 3.500 |
| High resolution limit [Å] | 3.240 | 3.240 |
| Number of reflections | 2954 | 580 |
| <I/σ(I)> | 3.1 | |
| Completeness [%] | 100.0 | |
| Redundancy | 14.7 | |
| CC(1/2) | 0.999 | 0.998 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | 4%(v/v) tacsimate (pH 4.0) and 12%(w/v) PEG 3,350 |