1YOZ
Predicted coding region AF0941 from Archaeoglobus fulgidus
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-BM |
| Synchrotron site | APS |
| Beamline | 17-BM |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2004-11-20 |
| Detector | CUSTOM-MADE |
| Wavelength(s) | 0.97946 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 72.492, 72.492, 165.271 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 62.750 - 2.000 |
| R-factor | 0.23435 |
| Rwork | 0.231 |
| R-free | 0.30031 |
| Structure solution method | SAD |
| RMSD bond length | 0.018 |
| RMSD bond angle | 1.641 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | SnB |
| Refinement software | REFMAC (5.2.0005) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 63.000 | 2.020 |
| High resolution limit [Å] | 1.950 | 1.950 |
| Number of reflections | 17895 | |
| <I/σ(I)> | 56.67 | 8.1 |
| Completeness [%] | 99.8 | 99.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 297 | 2.5M (NH4)2SO4, 0.1M Tris-HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 297K |