Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1YMT

Mouse SF-1 LBD

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]100
Detector technologyCCD
Collection date2004-08-28
DetectorADSC QUANTUM 4
Wavelength(s)1.03326
Spacegroup nameP 41 21 2
Unit cell lengths73.853, 73.853, 117.014
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution24.090 - 1.200
R-factor0.197
Rwork0.197
R-free0.21400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1PK5 (mLRH-1 LBD)
RMSD bond length0.017
RMSD bond angle1.800
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS (1.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0001.320
High resolution limit [Å]1.2001.200
Rmerge0.061
Number of reflections95280
<I/σ(I)>38
Completeness [%]94.0100
Redundancy13.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52958 mg/ml mSF-1, 6X molar excess of mSHP peptide, 0.1 M Tris, 14% PEG 8000, 5% isopropanol, 15% xylitol, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 295K

218500

PDB entries from 2024-04-17

PDB statisticsPDBj update infoContact PDBjnumon