1YIH
T-to-T(High) quaternary transitions in human hemoglobin: betaP100A oxy (2.2MM IHP, 20% PEG) (1 test set)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 169 |
Detector technology | IMAGE PLATE |
Collection date | 2001-05-25 |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 96.900, 99.500, 66.100 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 2.000 |
Rwork | 0.183 |
R-free | 0.24700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1y7c |
RMSD bond length | 0.011 |
RMSD bond angle | 0.027 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | X-PLOR |
Refinement software | PROLSQ |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.715 | 2.160 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.046 | 0.134 |
Number of reflections | 38030 | |
<I/σ(I)> | 12.7 | 5.2 |
Completeness [%] | 87.7 | 77.7 |
Redundancy | 2.5 | 2.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | batch | 7 | 298 | 10% PEG 6000, 10 MM POTASSIUM PHOSPHATE, 100 MM POTASSIUM CHLORIDE, 3 MM SODIUM DITHIONITE, 10 MG/ML DEOXYHB, 1 ATM N2, pH 7.0, batch, temperature 298.0K |