1YG6
ClpP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X25 |
Synchrotron site | NSLS |
Beamline | X25 |
Temperature [K] | 99 |
Detector technology | CCD |
Collection date | 2002-06-06 |
Detector | BRANDEIS - B4 |
Wavelength(s) | 0.98 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 192.500, 103.300, 159.000 |
Unit cell angles | 90.00, 98.40, 90.00 |
Refinement procedure
Resolution | 30.000 - 1.900 |
R-factor | 0.228 |
Rwork | 0.221 |
R-free | 0.25100 |
Structure solution method | FOURIER SYNTHESIS |
Starting model (for MR) | RESIDUES 20-193 1tys.PDB |
RMSD bond length | 0.011 |
RMSD bond angle | 1.800 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 1.850 |
Rmerge | 0.088 |
Number of reflections | 247428 |
<I/σ(I)> | 30 |
Completeness [%] | 95.9 |
Redundancy | 5.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.2 | 298 | mpd, mes, pH 6.2, VAPOR DIFFUSION, SITTING DROP, temperature 298K |