1WKG
Acetylornithine aminotransferase from thermus thermophilus HB8
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 180 |
Detector technology | IMAGE PLATE |
Collection date | 2003-07-25 |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 71.270, 69.790, 140.500 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 2.250 |
Rwork | 0.226 |
R-free | 0.28880 |
Structure solution method | MOLECULAR REPLACEMENT |
Phasing software | AMoRE |
Refinement software | CNS (1.0) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.050 |
Number of reflections | 261469 |
Completeness [%] | 95.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | PEG8000, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |