1WHO
ALLERGEN PHL P 2
Experimental procedure
Source type | ROTATING ANODE |
Source details | RIGAKU RUH2R |
Temperature [K] | 290 |
Detector technology | AREA DETECTOR |
Collection date | 1995 |
Detector | SIEMENS-NICOLET X100 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 39.312, 64.605, 36.090 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 8.000 - 1.900 |
Rwork | 0.182 |
Structure solution method | MIR |
RMSD bond length | 0.010 |
RMSD bond angle | 0.027 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASES |
Refinement software | PROFFT |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 24.000 |
High resolution limit [Å] | 1.900 |
Rmerge | 0.038 |
Number of reflections | 6392 |
Completeness [%] | 83.3 |
Redundancy | 2.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 4.6 | CRYSTALLIZED FROM 24% PEG 4000 SOLUTION., pH 4.6 |