T STATE HUMAN HEMOGLOBIN [ALPHA V96W], ALPHA AQUOMET, BETA DEOXY

Experimental procedure
Source typeROTATING ANODE
Source detailsRIGAKU RUH2R
Temperature [K]293
Detector technologyAREA DETECTOR
Collection date1995-02
DetectorSIEMENS
Spacegroup nameP 1 21 1
Unit cell lengths63.271, 83.416, 53.799
Unit cell angles90.00, 99.54, 90.00
Refinement procedure
Resolution25.000 - 1.900
R-factor0.169
Rwork0.169
Structure solution methodDIFFERENCE FOURIER
Starting model (for MR)1dxu
RMSD bond length0.009
RMSD bond angle1.200
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareX-PLOR (3.851)
Refinement softwareX-PLOR (3.851)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0001.990
High resolution limit [Å]1.9001.900
Rmerge0.067
Number of reflections39687
Completeness [%]91.375.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

226707

PDB entries from 2024-10-30