1VCY

VVA2 isoform

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU300
Temperature [K]133
Detector technologyIMAGE PLATE
Collection date2003-10-08
DetectorRIGAKU RAXIS IV
Wavelength(s)1.5418
Spacegroup nameP 42 2 2
Unit cell lengths56.107, 56.107, 132.427
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.510 - 2.600
Rwork0.225
R-free0.27200
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1pp0
RMSD bond length0.006
RMSD bond angle1.200
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS (1.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.5102.720
High resolution limit [Å]2.6002.600
Rmerge0.072
Number of reflections7022
<I/σ(I)>14.1
Completeness [%]99.7100
Redundancy13.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.6298ammonium sulfate, PEGMME 5000, malonic acid, pH 4.6, VAPOR DIFFUSION, HANGING DROP, temperature 298K