1URI
AZURIN MUTANT WITH MET 121 REPLACED BY GLN
Experimental procedure
Detector technology | DIFFRACTOMETER |
Collection date | 1991-06-02 |
Detector | ENRAF-NONIUS FAST |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 75.480, 74.340, 98.200 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 8.000 - 1.940 |
R-factor | 0.173 |
Rwork | 0.173 |
RMSD bond length | 0.011 |
RMSD bond angle | 2.834 |
Data reduction software | MADNES |
Phasing software | X-PLOR |
Refinement software | X-PLOR |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 9999.000 * | |
High resolution limit [Å] | 1.940 * | 1.940 * |
Rmerge | 0.077 | |
Total number of observations | 58815 * | |
Number of reflections | 16824 | |
Completeness [%] | 79.0 | 27.2 * |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion * | 5.2 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 16 (mg/ml) | |
2 | 1 | drop | Na, K phosphate | 0.1 (M) | |
3 | 1 | drop | ammonium sulfate | 2 (M) | |
4 | 1 | reservoir | ammonium sulfate | 60 (%(w/v)sat) |