1ULC
CGL2 in complex with lactose
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2002-04-06 |
Detector | MARRESEARCH |
Wavelength(s) | 1.5418 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 65.220, 65.220, 240.286 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.290 - 2.600 |
Rwork | 0.210 |
R-free | 0.26600 |
Structure solution method | SAD (I) and Molecular Replacement |
RMSD bond length | 0.006 |
RMSD bond angle | 1.400 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.290 | 2.690 |
High resolution limit [Å] | 2.600 | 2.600 |
Number of reflections | 15351 | |
<I/σ(I)> | 20.6 | 2.4 |
Completeness [%] | 98.4 | 85.2 |
Redundancy | 9.5 | 5.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.3 | 291 | PEG 3350, PEG 400, sodium phosphate, sodium chloride, pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 291K |
1 | VAPOR DIFFUSION, HANGING DROP | 7.3 | 291 | PEG 3350, PEG 400, sodium phosphate, sodium chloride, pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 291K |