Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | MAX II BEAMLINE I711 |
| Synchrotron site | MAX II |
| Beamline | I711 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Wavelength(s) | 1.0760 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 118.757, 121.373, 129.086 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.840 - 2.200 |
| R-factor | 0.215 |
| Rwork | 0.215 |
| R-free | 0.26800 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.300 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Refinement software | CNX (2002) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 36.800 | 2.340 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Number of reflections | 74736 | |
| Completeness [%] | 78.5 | 36.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | PEG 4000, SODIUM ACETATE, TRIS, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |