Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X25 |
Synchrotron site | NSLS |
Beamline | X25 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2003-07-20 |
Detector | ADSC QUANTUM 4 |
Spacegroup name | P 41 2 2 |
Unit cell lengths | 108.541, 108.541, 249.158 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.220 - 3.100 |
R-factor | 0.24712 |
Rwork | 0.246 |
R-free | 0.27867 |
Structure solution method | MAD |
RMSD bond length | 0.006 |
RMSD bond angle | 1.333 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | MLPHARE |
Refinement software | REFMAC (5.1.24) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 3.100 |
Number of reflections | 24640 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6.8 | pH 6.80 |