1U3P
IspF native
Experimental procedure
| Experimental method | SINGLE WAVELENGTH | 
| Source type | ROTATING ANODE | 
| Source details | RIGAKU RU200 | 
| Temperature [K] | 100 | 
| Detector technology | IMAGE PLATE | 
| Collection date | 2001-04-02 | 
| Detector | MARRESEARCH | 
| Wavelength(s) | 1.541 | 
| Spacegroup name | I 21 3 | 
| Unit cell lengths | 144.150, 144.150, 144.150 | 
| Unit cell angles | 90.00, 90.00, 90.00 | 
Refinement procedure
| Resolution | 8.000 - 2.850 | 
| R-factor | 0.23 | 
| Rwork | 0.226 | 
| R-free | 0.23700 | 
| Structure solution method | MIR | 
| RMSD bond length | 0.012 | 
| RMSD bond angle | 1.840 | 
| Data reduction software | MOSFLM | 
| Data scaling software | SCALA | 
| Phasing software | MLPHARE | 
| Refinement software | X-PLOR | 
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 20.000 | 
| High resolution limit [Å] | 2.850 | 
| Rmerge | 0.074 | 
| Number of reflections | 11403 | 
| Completeness [%] | 97.4 | 
| Redundancy | 4.3 | 
Crystallization Conditions
| crystal ID | method | pH | temperature | details | 
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | ammonium formate, pH 7, VAPOR DIFFUSION, SITTING DROP, temperature 293K | 