1TFA
OVOTRANSFERRIN, N-TERMINAL LOBE, APO FORM
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | MACSCIENCE M18X |
Temperature [K] | 293 |
Detector technology | AREA DETECTOR |
Collection date | 1997-07-15 |
Detector | SIEMENS |
Spacegroup name | P 63 2 2 |
Unit cell lengths | 125.170, 125.170, 87.260 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 7.000 - 1.900 |
R-factor | 0.187 |
Rwork | 0.187 |
R-free | 0.24300 |
Structure solution method | MIR |
RMSD bond length | 0.012 |
RMSD bond angle | 24.200 * |
Data reduction software | SAINT |
Data scaling software | SAINT |
Phasing software | PHASES |
Refinement software | X-PLOR (3.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 1.830 |
Number of reflections | 194748 |
Completeness [%] | 95.5 |
Redundancy | 5.62 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 6 | 20 * | pH 6.0 |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 44.4 (mg/ml) | |
2 | 1 | drop | Bis Tris-HCl | 0.05 (M) | |
3 | 1 | reservoir | Bis-Tris | 0.05 (M) | |
4 | 1 | reservoir | ammonium sulfate | 52 (%) |