Effect of Shuttle Location and pH Environment on H+ Transfer in Human Carbonic Anhydrase II

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]293
Detector technologyIMAGE PLATE
DetectorRIGAKU RAXIS IV
Wavelength(s)1.54
Spacegroup nameP 1 21 1
Unit cell lengths42.697, 41.620, 72.831
Unit cell angles90.00, 104.49, 90.00
Refinement procedure
Resolution20.000 - 2.000
Rwork0.134
R-free0.17300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2cba
RMSD bond length0.022
RMSD bond angle1.897
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareREFMAC (5.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.070
High resolution limit [Å]2.0002.000
Number of reflections16751
Completeness [%]99.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP9.327750 mM Tris-Cl pH 9.3, 2.5 M ammonium sulfate, VAPOR DIFFUSION, HANGING DROP, temperature 277K