1TBT
Effect of Shuttle Location and pH Environment on H+ Transfer in Human Carbonic Anhydrase II
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 293 |
Detector technology | IMAGE PLATE |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.54 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 42.632, 41.564, 72.823 |
Unit cell angles | 90.00, 104.56, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.000 |
Rwork | 0.130 |
R-free | 0.18400 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2cba |
RMSD bond length | 0.024 |
RMSD bond angle | 1.863 |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | REFMAC (5.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.070 |
High resolution limit [Å] | 2.000 | 2.000 |
Number of reflections | 15878 | |
Completeness [%] | 91.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 277 | 50 mM Tris-Cl pH7.0, 2.5 M ammonium sulfate, VAPOR DIFFUSION, HANGING DROP, temperature 277K |