1TBJ
H141A mutant of rat liver arginase I
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X25 |
Synchrotron site | NSLS |
Beamline | X25 |
Temperature [K] | 110 |
Detector technology | IMAGE PLATE |
Collection date | 2000-10-20 |
Detector | MARRESEARCH |
Wavelength(s) | 0.98 |
Spacegroup name | P 32 |
Unit cell lengths | 87.815, 87.815, 110.916 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.800 - 2.800 |
R-factor | 0.263 |
Rwork | 0.263 |
R-free | 0.29900 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.014 |
RMSD bond angle | 1.700 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.910 |
High resolution limit [Å] | 2.800 | 2.800 |
Number of reflections | 24210 | |
Completeness [%] | 91.6 | 95.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 277 | bicine, PEG8000, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |