1T9N
Effect of Shuttle Location and pH Environment on H+ Transfer in Human Carbonic Anhydrase II
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 293 |
| Detector technology | IMAGE PLATE |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 42.866, 41.539, 72.943 |
| Unit cell angles | 90.00, 104.71, 90.00 |
Refinement procedure
| Resolution | 20.000 - 2.000 |
| Rwork | 0.195 |
| R-free | 0.20900 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2cba |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.553 |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.070 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Number of reflections | 15898 | |
| Completeness [%] | 90.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.1 | 277 | 50 mM MES, 2.5 M ammonium sulfate, PH 5.1, VAPOR DIFFUSION, HANGING DROP, temperature 277K |