Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1T8X

r106g kdo8ps with pep and a5p

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Temperature [K]100
Detector technologyIMAGE PLATE
DetectorRIGAKU RAXIS IV
Spacegroup nameP 31 2 1
Unit cell lengths84.375, 84.375, 160.459
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution54.020 - 1.800
Rwork0.197
R-free0.24200
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)1fww
RMSD bond length0.009
RMSD bond angle1.500
Data reduction softwareCrystalClear ((MSC/RIGAKU))
Data scaling softwared*TREK
Phasing softwareCNS
Refinement softwareCNS (1.1)
Data quality characteristics
 Overall
Low resolution limit [Å]54.020
High resolution limit [Å]1.800
Number of reflections60408
<I/σ(I)>4.5
Completeness [%]96.6
Redundancy9.12
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.7277PEG, Na-acetate, pH 4.7, VAPOR DIFFUSION, HANGING DROP, temperature 277K

218196

PDB entries from 2024-04-10

PDB statisticsPDBj update infoContact PDBjnumon