1SVP
SINDBIS VIRUS CAPSID PROTEIN
Experimental procedure
| Detector technology | IMAGE PLATE |
| Collection date | 1994-10-22 |
| Detector | RIGAKU RAXIS IIC |
| Spacegroup name | P 1 |
| Unit cell lengths | 29.000, 56.500, 60.830 |
| Unit cell angles | 93.10, 96.73, 94.93 |
Refinement procedure
| Resolution | 5.000 - 2.000 |
| R-factor | 0.184 |
| Rwork | 0.184 |
| R-free | 0.27900 |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.700 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | X-PLOR (3.1) |
| Refinement software | X-PLOR (3.1) |
Data quality characteristics
| Overall | |
| Rmerge | 0.036 |
| Redundancy | 2.63 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion, hanging drop * | Boege, U., (1989) J. Mol. Biol., 208, 79. * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | reservoir | PEG8000 | 8 (%(w/v)) | |
| 2 | 1 | reservoir | Tris | 100-200 (mM) | |
| 3 | 1 | drop | protein | 5-10 (mg/ml) | |
| 4 | 1 | drop | PEG8000 | 4 (%(w/v)) | |
| 5 | 1 | drop | Tris | 50-100 (mM) |