1SEQ
Fab MNAC13
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID14-1 |
| Synchrotron site | ESRF |
| Beamline | ID14-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2000-07-18 |
| Detector | MARRESEARCH |
| Wavelength(s) | 0.934 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 52.731, 67.546, 111.431 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 38.940 - 1.780 |
| R-factor | 0.194 |
| Rwork | 0.194 |
| R-free | 0.23200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1bm3 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.500 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 39.000 | 1.830 |
| High resolution limit [Å] | 1.780 | 1.780 |
| Number of reflections | 38392 | |
| <I/σ(I)> | 8.2 | 1.1 |
| Completeness [%] | 99.5 | 99.6 |
| Redundancy | 5.9 | 4.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 289 | 2 M ammonium sulfate, 5%(v/v) 2-propanol, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 289K |