1RVZ
1934 H1 Hemagglutinin in complex with LSTC
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID14-1 |
| Synchrotron site | ESRF |
| Beamline | ID14-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2002-09-20 |
| Detector | ADSC QUANTUM 4 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 227.583, 131.522, 175.017 |
| Unit cell angles | 90.00, 110.07, 90.00 |
Refinement procedure
| Resolution | 20.000 - 2.250 |
| R-factor | 0.225 |
| Rwork | 0.225 |
| R-free | 0.25700 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ru7 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | CNS (1.0) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.330 |
| High resolution limit [Å] | 2.250 | 2.250 |
| Rmerge | 0.082 | 0.401 |
| Number of reflections | 206016 | |
| <I/σ(I)> | 14.6 | 2.9 |
| Completeness [%] | 89.9 | 52.2 |
| Redundancy | 11.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291 | PEG3350, TrisHCl, KSCN, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 291K |