1RPE
THE PHAGE 434 OR2/R1-69 COMPLEX AT 2.5 ANGSTROMS RESOLUTION
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ELLIOTT GX-13 |
Temperature [K] | 277 |
Detector technology | AREA DETECTOR |
Detector | SIEMENS |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 149.290, 64.290, 27.690 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 5.500 - 2.500 |
R-factor | 0.209 |
Refinement software | CORELS |
Data quality characteristics
Overall | |
High resolution limit [Å] | 2.500 |
Number of reflections | 6984 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.7 | 277 | pH 5.70, VAPOR DIFFUSION, HANGING DROP, temperature 277.00K |
Crystallization Reagents
ID | crystal ID | solution ID | reagent name | concentration | details |
1 | 1 | 1 | WATER | ||
2 | 1 | 1 | PEG 3000 | ||
3 | 1 | 1 | NACL | ||
4 | 1 | 1 | MGCL2 | ||
5 | 1 | 1 | MES | ||
6 | 1 | 1 | [CO(NH3)6]3+ |