1RAJ
Poliovirus Polymerase with a 68 residue N-terminal truncation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2002-01-01 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 87.710, 87.710, 107.340 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 30.000 - 2.500 |
| Rwork | 0.242 |
| R-free | 0.26200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1rdr |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.400 |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.590 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Rmerge | 0.062 | 0.569 |
| Number of reflections | 17009 | |
| <I/σ(I)> | 35 | 3.34 |
| Completeness [%] | 99.9 | 99.6 |
| Redundancy | 10 | 8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 289 | sodium formate, sodium chloride, HEPES, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 289K |