Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1QZL

GCATGCT + Cobalt

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsEMBL/DESY, HAMBURG BEAMLINE BW7B
Synchrotron siteEMBL/DESY, HAMBURG
BeamlineBW7B
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2003-08-19
DetectorMARRESEARCH
Wavelength(s)0.8416
Spacegroup nameP 62 2 2
Unit cell lengths24.789, 24.789, 91.818
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution30.570 - 2.850
R-factor0.24375
Rwork0.240
R-free0.33473
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.021
RMSD bond angle2.909
Data reduction softwareMOSFLM
Data scaling softwareCCP4 ((SCALA))
Refinement softwareREFMAC (5.1.24)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.6063.000
High resolution limit [Å]2.8502.850
Rmerge0.1570.288
Number of reflections522
<I/σ(I)>4.12.1
Completeness [%]96.799.5
Redundancy6.66.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.5290sodium cacodylate, Cobalt dichloride, potassium chloride, MPD, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 290K
Crystallization Reagents
IDcrystal IDsolution IDreagent nameconcentrationdetails
111sodium cacodylate
211Cobalt dichloride
311potassium chloride
411MPD
511H2O
612sodium cacodylate
712Cobalt dichloride
812MPD
912H2O

222926

PDB entries from 2024-07-24