1Q2H
Phenylalanine Zipper Mediates APS Dimerization
Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X12C |
Synchrotron site | NSLS |
Beamline | X12C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2002-01-01 |
Detector | BRANDEIS - B4 |
Wavelength(s) | 0.95000, 0.9174, 0.9211, 0.9208 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 69.740, 57.480, 51.720 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.000 - 1.700 |
Rwork | 0.250 |
R-free | 0.27000 |
Structure solution method | MAD |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | SOLVE |
Refinement software | CNS (1.0) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 1.700 |
Number of reflections | 19012 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 0.48-0.68 M sodium iodide, 2.5 % PEG 4K, 0.09 M sodium citrate, 10 mM DTT, pH 6.0, VAPOR DIFFUSION, HANGING DROP |