1PUC
P13SUC1 IN A STRAND-EXCHANGED DIMER
Experimental procedure
| Detector technology | AREA DETECTOR |
| Collection date | 1994-09-28 |
| Detector | XUONG-HAMLIN MULTIWIRE |
| Wavelength(s) | 1.5418 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 43.270, 55.280, 111.800 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 6.000 - 1.950 |
| R-factor | 0.187 |
| R-free | 0.24100 |
| RMSD bond length | 0.006 |
| RMSD bond angle | 24.472 * |
| Data reduction software | SDMS |
| Phasing software | X-PLOR (3.1) |
| Refinement software | TNT |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 * | |
| High resolution limit [Å] | 1.950 | 1.950 * |
| Rmerge | 0.049 | |
| Total number of observations | 53600 * | |
| Number of reflections | 9859 | |
| Completeness [%] | 97.5 | 81.4 * |
| Redundancy | 5.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion, sitting drop * | 7.8 * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | recombinant p13suc1 | 12 (mg/ml) | |
| 2 | 1 | drop | 38 (mM) | ||
| 3 | 1 | drop | Tris-HCl | 38 (mM) | |
| 4 | 1 | drop | PEG MME 2000 | 9 (%(w/v)) | |
| 5 | 1 | drop | CHAPS | 0.4 (%(w/v)) | |
| 6 | 1 | reservoir | PEG MME 2000 | 25 (%(w/v)) | |
| 7 | 1 | reservoir | 0.1 (M) | ||
| 8 | 1 | reservoir | Tris-HCl | 0.1 (M) |