1OXA
CYTOCHROME P450 (DONOR:O2 OXIDOREDUCTASE)
Experimental procedure
Detector technology | AREA DETECTOR |
Detector | SIEMENS-NICOLET X100 |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 54.160, 79.670, 99.480 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 2.100 |
R-factor | 0.196 |
Rwork | 0.196 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.342 |
Data reduction software | XENGEN |
Phasing software | X-PLOR |
Refinement software | X-PLOR |
Data quality characteristics
Overall | |
High resolution limit [Å] | 2.100 |
Rmerge | 0.054 |
Total number of observations | 127949 * |
Number of reflections | 23771 |
Completeness [%] | 91.0 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 8.5 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | reservoir | PEG4000 | 24 (%) | |
2 | 1 | reservoir | sodium acetate | 0.2 (M) | |
3 | 1 | reservoir | Tris-HCl | 0.1 (M) |