1OCW

Free conformation Ab2 of the IgE SPE-7

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2002-08-15
DetectorMARRESEARCH
Spacegroup nameI 4
Unit cell lengths79.545, 79.545, 67.703
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution28.170 - 2.000
R-factor0.252

*

R-free0.21000

*

Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1oaq
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareAMoRE
Refinement softwareSHELXL-97
Data quality characteristics
 Overall
Low resolution limit [Å]28.170
High resolution limit [Å]2.010
Rmerge0.051
Number of reflections13952
Completeness [%]94.4
Redundancy9.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
150.1M HEPES, PH7.5, 70% MPD, pH 5.00

227111