1O1I
Cyanomet hemoglobin (A-GLY-C:V1M,L29F,H58Q; B,D:V1M,L106W)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | SIEMENS |
| Temperature [K] | 295 |
| Detector technology | IMAGE PLATE |
| Collection date | 1998-04-15 |
| Detector | RIGAKU RAXIS IIC |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 56.671, 56.671, 185.834 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 8.000 - 2.300 |
| R-factor | 0.174 |
| R-free | 0.26700 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1hho |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.013 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | CNS |
| Refinement software | SHELXL-97 |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.500 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Rmerge | 0.053 | 0.237 |
| Number of reflections | 13935 | |
| <I/σ(I)> | 22.5 | 5.45 |
| Completeness [%] | 97.6 | 97.1 |
| Redundancy | 3.27 | 3.27 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 6.7 | pH 6.70 |