Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL11-1 |
| Synchrotron site | SSRL |
| Beamline | BL11-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2002-05-27 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.98 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 52.550, 92.670, 101.050 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 29.540 - 2.000 |
| R-factor | 0.248 |
| Rwork | 0.248 |
| R-free | 0.29000 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1k6z |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.100 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP ((CCP4)) |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 45.720 | 2.010 |
| High resolution limit [Å] | 1.980 | 1.980 |
| Rmerge | 0.037 | 0.235 |
| Number of reflections | 34752 | |
| <I/σ(I)> | 30.6 | 5 |
| Completeness [%] | 89.2 | |
| Redundancy | 4.4 | 4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.7 | 291 | PEG 400, ammonium sulphate, sodium chloride, hepes, TCEP, pH 7.7, VAPOR DIFFUSION, HANGING DROP, temperature 291K |